Flaw Detecting Method Sensitivity Name of Device Applicable Tube Dimension (OD, mm)
Out side Diameter Micrometer 9.53 to 100.00
  Tube dimensional Flaw Manual Check Inside Diameter Three leg Bore Micrometer 15.00 to 96.00
Inside Diameter Bore Dial for DOM Tube 30.00 to 96.00
Thickness Micrometer 0.70 to 7.00
Length Measuring Tap 1 Mtr
  Hydraulic Press weld check Tube Weld Check on Zero & Ninety Degree   100 Ton Hydraulic Press   All Sizes
Dye Penetrate Weld Test Weld Quality Dye Penetrate All Tube
Universal Testing Mechanical Strength Universal Testing Machine All Tube & Strip
  Hardness Hardness Test Rockwell Hardness Tester All Tube & Strip
Vickers Hardness Tester 0.70 to 1.00
  Micro Scope Testing Micro Structure of Annealed Tube Micro Scope 400X & Stereo Micro Scope All Size Annealed Tube
Surface Roughness Testing DOM Tube I.D Surface Tester ID requested DOM Tube
Off Line Eddy Testing Weld and Surface Test Eddy Test With De-Magnetizing All Tube